您好,欢迎来到半岛官网网站 网站!

服务热线

当前位置: 首页- 新闻中心> 公司动态
常见问题
新闻中心

济南机箱机柜分享配电柜除湿的有效办法!

发布时间:2021-01-08来源://www.aqfitlab.com/浏览量:

很多电工普遍反映,在对配电柜进行维护的时候会发现配电柜内或多或少都会有潮湿的现象,有的配电柜潮湿特别严重,周围的线缆被霉点覆盖,配电柜内的金属元器件也是锈迹斑斑,而且还经常出现跳闸的情况,有的甚至引发火灾。
Many electricians generally reflect that when maintaining the distribution cabinet, they will find that there is more or less moisture in the distribution cabinet. Some distribution cabinets are very humid, the surrounding cables are covered by mildew, and the metal components in the distribution cabinet are rusty, and they often trip, and some even cause fire.
其实配电柜生锈发霉多是因为潮湿所引起的,当发现有潮湿现象的时候应该立刻采取措施进行防潮治理,接下来 济南机箱机柜给大家分享一下配电柜除湿的有效办法。
In fact, the distribution cabinet rust and mildew is mostly caused by moisture, when it is found that there is a moisture phenomenon, we should immediately take measures for moisture-proof treatment, next Jinan chassis cabinet to share with you the effective method of distribution cabinet dehumidification.
配电柜除湿的有效办法:
The effective methods of dehumidification for distribution cabinet are as follows:
利用停电机会清擦设备,使配电箱内保持清洁。
Make use of the power cut opportunity to clean the equipment to keep the distribution box clean.
密闭配电柜。高压室的通风窗、通风口,按规程规定落实空气过滤措施。使高压室内空气保持清洁。
Closed distribution cabinet. The ventilation windows and vents of the high pressure chamber shall be provided with air filtration measures according to the regulations. Keep the air in the high pressure room clean.
配电柜潮湿怎么办,配电柜除湿的有效办法
How to deal with the humidity of power distribution cabinet? The effective way of dehumidification of power distribution cabinet
济南机箱机柜
配电柜下边的电缆沟、电缆隧道、电缆孔洞作防水密封,加装自然通风排潮通道,保持电缆隧道空气干燥。
The cable trench, cable tunnel and cable hole under the distribution cabinet shall be waterproof and sealed, and the natural ventilation and moisture drainage channel shall be installed to keep the air in the cable tunnel dry.
室外配电柜可加装雨搭。
Outdoor power distribution cabinet can be equipped with rain hook.
及时消除配电柜顶漏雨缺陷。
Timely eliminate the rain leakage defect on the top of the distribution cabinet.
出线户内封闭式母线桥底部铁板改为钢丝网板,或横向开一个l00mm的缝隙(靠近墙体的部位),雨水由出线穿墙套管固定钢板处进人时,可以从缝隙排出。不能进人开关柜。
The iron plate at the bottom of the indoor enclosed bus bridge of the outgoing line is changed into steel mesh plate, or a 100 mm gap is opened horizontally (near the wall). When the rainwater enters from the fixed steel plate of the outgoing line through the wall bushing, it can be discharged from the gap. Do not enter the switch cabinet.
对于已经出现凝露状况,并且比较严重的话,建议使用SPR-NL防凝露装置或HK-SEPRI-T顶置除湿系统,按湿度自动控制,排除柜内水分。
If the condensation has occurred and is serious, it is recommended to use spr-nl anti condensation device or hk-sepri-t overhead dehumidification system to automatically control the humidity and remove the moisture in the cabinet.
以上是" 济南机箱机柜对配电柜除湿的有效办法"的介绍,希望对大家有所帮助,如想了解更多精彩内容请多多关注我们的网站。
The above is the introduction of "Jinan cabinet dehumidification of power distribution cabinet effective method", hope to help you, if you want to know more wonderful content, please pay more attention to our website.
首页首页 产品产品 电话电话 置顶置顶
Baidu
map